Variax

3p25Secondary analysis · 01 Call

Variax. GPU secondary analysis, reads to variants in minutes.

Alignment, variant calling and QC on GPUs. One 30x genome in minutes, with every tool version recorded for validation.

Variax · run vx-0412Example
AlignBWA-MEM class, GPU6 min
Sort + dedupGPU3 min
BQSRGPU2 min
Calldeep-learning caller, GPU11 min
QCcoverage, Ti/Tv, contaminationPass

Invented run of one 30x genome on one 8-GPU node.

3p21Capabilities

What it does.

01

GPU alignment

Reads to sorted, deduplicated alignments with Parabricks.

02

Germline and somatic calling

Germline for rare disease; tumour-normal for oncology.

03

Deep-learning callers

DeepVariant-class callers on GPU, alongside classical ones.

04

QC that flags early

Coverage, contamination, sex check and relatedness, with anomaly detection on run metrics.

05

Versioned pipelines

Every tool, model and reference pinned and recorded per run.

06

Concordance reports

Runs against reference truth sets you choose, for validation.

3p15Runtime

Where the hours go today.

30x genome, align and call

≈ 10 h≈ 25 min

Exome, align and call

≈ 1.5 h≈ 5 min

Tumour-normal pair, somatic

≈ 15 h≈ 45 min

CPU pipeline, typical rangeVariax on GPUs, design target

Example CPU figures are typical ranges labs describe for multi-core servers; Variax figures are design targets for one 8-GPU node. Neither is a measurement.

3p11.2How it works

One case, start to finish.

  1. 01On arrival

    Receive

    FASTQ, BAM or CRAM from the sequencer or LIMS.

  2. 02Minutes

    Align

    GPU alignment, sorting and deduplication.

  3. 03Minutes

    Call

    Germline or somatic calling on GPU.

  4. 04Seconds

    Check

    QC metrics and anomaly flags.

  5. 05Seconds

    Hand off

    VCF and alignments to Pathova and your storage.

3q12Specification

The details.

Variax specification (draft)
ItemDetail
InputsFASTQ, BAM, CRAM; GRCh38 (GRCh37 supported)
OutputsBAM/CRAM, VCF and gVCF, QC report, run manifest
EnginesNVIDIA Parabricks, CUDA, RAPIDS for QC
ModesBatch and streaming; cloud, on premises or on Locira
ValidationConcordance against truth sets; pinned versions
StatusIn design. Early access with founding labs.

3q22In the pipeline

Where it sits.

3q31Questions

Straight answers.

Does Variax replace our pipeline?

It can, or it can run beside it. Many labs keep their pipeline and use Variax for speed on validated assays.

Are the results the same every time?

Yes, for the same inputs and pinned versions. Every run records its versions in the manifest.

Which sequencers?

Short-read platforms first. Long-read support is planned; tell us what you run.

3qterNext step

Bring us a case you have already solved.

Choose a case with a confirmed answer and the data behind it. We run it through Phenalis under a data agreement and show you, side by side with your own report, the time it took, the shortlist and the evidence we found.